See the guidelines below when setting up your GPS system to ensure best vertical accuracy.

When setting up the base station, do the following:
•   Mount the base antenna level (within 1-2 degrees).
•   Install the base receiver on a tripod and ensure that the antenna is more than 100 feet (35 m) away from any metal objects or structures (such as laser trailers, pump structures, aluminized crop covering), regardless of their height relationship to the antenna.
•   Make sure that the remote radio antenna that is included in the mobile base station kit points down, or is placed at least 3 meters (approximately 6 feet) away.
•   Place the base receiver in the field of operation as close as possible
•   Place all mobile base stations less than 1 mile away from the operation area (the closer in proximity the less the maximum error and number of events).
•   Complete a 5 minute average each time a new base location is established

Source:
Best Vertical GPS Performance by Trimble

Tips and Tricks

  1. NRCS SCS Engineering Field Handbook
  2. Water Control Structures
  3. Smoothing Distance
  4. Erosion Control Banks & Waterway
  5. Drainage Design Solutions of Different Topographies
  6. Runoff vs Slope
  7. Trimble Field Level II Do Not Show the .gps File
  8. Minimum Recommended Smoothing Distance For Export To Trimble Field Level 2
  9. GPS Base Station Setup For Best Vertical Accuracy
  10. How to Survey with Trimble FMX
  11. How Easy is OptiSurface to Use for the Average Farmer?
  12. Balancing Earthworks in the Field
  13. Landform Design Slopes and Smoothing
  14. Export Proposed Topography to AutoCAD
  15. Surface Irrigation Designs with Variable Slope
  16. OptiSurface Designer Import and Export Format
  17. Importing Multiple Survey Files to OSD
  18. Can Drone Or LIDAR Surveys be used with OptiSurface?
  19. Calculation Grid Spacing and Export Grid Spacing
  20. How to Survey a Field for Landforming Design
  21. Loading .gps File in FMX
  22. Designing a Field in Sections
  23. Using an Old OSD File versus a New Survey
  24. No Master Benchmark on Imported Survey File
  25. Displaying Secondary Benchmarks
  26. Import Error for xyz File Due to Encoding Format
  27. OptiSurface4D: Bounded By Ridges
  28. Can OptiSurface handle curved rows in Drainage Analysis & Runoff Analysis?
  29. Reverse Grades to Main Slope
  30. Measuring Culvert Invert Level
  31. Surveying a 1000-Ha Field
  32. GPS Coordinate System Check
  33. Does A Normal UTM Zone Coordinate Need To Be Trimmed To x Digits?
  34. Can You Import Data Directly From GPS System?
  35. Converting Latitude/Longitude to Easting/Northing
  36. Surveying With Any GPS Equipment and Exporting to a gps file for the Trimble FMX
  37. DGPS Post Treating System with 5cm Precision For Landforming
  38. Exporting to Trimble FMX Field Level
  39. Can I Survey with a GPS System on an ATV?
  40. Standard NMEA GPGGA txt File to Import into OptiSurface Designer
  41. 900 Acres: Cut that large survey down.
  42. Export Options for Data Layers
  43. Import Two or More Survey Files to Reach Minimum Area
  44. Different Row Slope Directions In One Field
  45. Does OptiSurface allow for multiple grade breaks per design, taildrains roads, pads etc?
  46. Can I View DTM/Topography In Plan View Or 3D Type View When Doing A Design?
  47. Adjust the Bands in the Legend
  48. Design for a 1000-Ha Field
  49. Would It Be Possible That The Numbers In The Boundary Zone Appear In The New Subzone Created?
  50. Grade Of Best Fit And Splitting The Field Into Boundaries
  51. Acceptable Minimum Slopes
  52. Incorrect Area in OptiSurface
  53. Valley Subzone Not Behaving as Expected
  54. Difference Between Breaklines And Subzones
  55. Alignment of Furrow/Bed Direction with OptiSurface Design Mainslope Direction
  56. Subzones Settings Over Ride Boundary Zone Settings
  57. Printing the Maps
  58. Print Size

Feedback and Knowledge Base